 Part No: CMI-1240 Description: piezo audio indicator
Date: 9/19/2006 Unit: mm Page No: 1 of 5
Specifications
Resonant frequency Operating voltage Current consumption Sound pressure level Rated voltage Tone Operating temperature Storage temperature Dimensions Weight Material Terminal RoHS 4.0 KHz 0.5 3 ~ 20 V dc 8 mA max. at 12 V dc 83 db min. at 10 cm / 12 V dc 12 V dc Continuous -30 ~ +70 C -40 ~ +80 C L16.9 x W16.9 x H7.8 mm 2.6 g max. PPS UL-94 V-0 (Black) SMD type (Au Plating) yes
Appearance Drawing
Tolerance: 0.5
CUI.Inc.
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CMI-1240 Description: piezo audio indicator
Date: 9/19/2006 Unit: mm Page No: 2 of 5
Voltage: Sound Pressure Level / Voltage: Current Consumption
at 10cm 110 105 100 Sou Pressure Level(dB) nd 95 90 85 75 70 25 20 15 10 5 3 6 9 12 Voltage(VDC) 15 18 20 0 Current Consumption(mA) 80
P
I
Measurement Method
S.P.L. Measuring Circuit
Mic : RION S.P.L meter UC30 or equivalent S.G : Hewlett Packard 33120A Function Generator or equivalent
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CMI-1240 Description: piezo audio indicator
Date: 9/19/2006 Unit: mm Page No: 3 of 5
Mechanical Characteristics
Item Solderability Soldering Heat Resistance Terminal Mechanical Strength Evaluation Standard Test Condition 95% of the surface must be Lead terminals are immersed in solder bath covered with fresh solder. of 270 5C for 3 1 seconds. No interference in operation. The product follows the reflow temperature curve to test its reflow thermo stability. Lead pads should be soldered onto the pc board and the force of 9.8N (1.0kg) should be No damage or cutting off. applied behind the part for 10 seconds. The buzzer should be measured after applying The value of oscillation frequency/current consumption a vibration amplitude of 1.5 mm with 10 to should be within 10% of the 55 Hz band of vibration frequency to each of initial measurements. The SPL the 3 perpendicular directions for 2 hours. should be within 10dB compared The part should be dropped from a height of with the initial measurement. 75 cm onto a 40 mm thick wooden board 3 times in 3 axes (X, Y, Z) for a total of 9 drops.
Vibration
Drop Test
Environment Test
Item High temp. test Low temp. test Humidity test Temp. cycle test Evaluation Standard Test Condition After being placed in a chamber at +80C for 240 hours. After being placed in a chamber at -40C for 240 hours. After being placed in a chamber at +40C and The buzzer will be measured after 905% relative humidity for 240 hours. The part should be subjected to 5 cycles. One being placed at +25C for 4 hours. The value of the cycle should consist of: oscillation frequency/current +80 C consumption should be within 10% compared to the initial measurements. The SPL should +25 C +25 C be within 10dB compared to the -40 C initial measurements.
0.5hr 0.5hr 0.25 0.5hr 0.5hr 0.5hr 0.25
3hours
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CMI-1240 Description: piezo audio indicator
Date: 9/19/2006 Unit: mm Page No: 4 of 5
Reliability Test
Item Operating (Life Test) Test Condition 1. Continuous life test: The part will be subjected to 48 hours of continuous operation at +55C with 12 V dc applied. 2. Intermittent life test: A duty cycle of 1 minute on, 1 minute off, a minimum of 5,000 times at room temp (+25 2C) with 12 V dc applied. Evaluation Standard The buzzer will be measured after being placed at +25C for 4 hours. The value of the oscillation frequency/current consumption should be 10% compared to the initial measurements. The SPL should be within 10dB compared to the initial measurements.
Test Conditions
Standard Test Condition Judgement Test Condition a) Tempurature: +5 ~ +35C a) Tempurature: +25 2C b) Humidity: 45 - 85% b) Humidity: 60 - 70% c) Pressure: 860-1060 mbar c) Pressure: 860-1060 mbar
Recommended Temperature Profile for Reflow Oven
SMT Reflow Temperature Profile (Pb_Free)
Peak Temp 260 C 255 C 20~40 sec
217C C 150C 200C
60~180 sec
60~150sec
Time [sec]
Phone: 800.275.4899 Fax: 503.612.2381 www.cui.com 20050 SW 112th Ave. Tualatin, OR 97062
Part No: CMI-1240 Description: piezo audio indicator
Date: 9/19/2006 Unit: mm Page No: 5 of 5
Packaging
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062


▲Up To Search▲   

 
Price & Availability of CMI-1240

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X